# Analytics snippet placeholder — HearthNodes (gatherer.top) # Paste the measurement snippet here (server.js inlines any content that contains # a markup tag into on every page). No GA4 property is assigned to this # site yet, so leave this file as comments only and the build emits no tracking # code.
HearthNodesgatherer.top 已发布 27/28 EN 中文

管路防冻:在水温降到 2 °C 前开启远端细流并预警

最暴露管段上的管夹式温度传感器在 4 °C 预警、在 2 °C 时开启 0.4 L/min 的细流——足以让 15 毫米铜管在 -8 °C 的夜里保持流动,而整夜浪费不超过 12 升水。

协议 · thread 延迟 · 120000 ms 供电 · mains 发布 · 2026-10-20 3 devices
自动化 YAML water-freeze-trickle-warning.yaml
# HearthNodes recipe 23 - pipe freeze guard
alias: "Water - freeze guard trickles the far tap"
id: hn_water_freeze_trickle
description: "Warn at 4 C, trickle at 2 C, close after 15 minutes above 6 C"
mode: restart
max_exceeded: silent

trigger:
  - platform: numeric_state
    entity_id: sensor.exposed_pipe_temperature
    below: 4
    id: warn
  - platform: numeric_state
    entity_id: sensor.exposed_pipe_temperature
    below: 2
    id: trickle
  - platform: numeric_state
    entity_id: sensor.exposed_pipe_temperature
    above: 6
    for: "00:15:00"
    id: release

variables:
  tap: valve.far_tap
  trickle_lpm: 0.4
  max_runtime_h: 10
  wind_chill: >-
    {{ states('sensor.outdoor_temperature') | float(10)
       - (states('sensor.wind_speed_kmh') | float(0) * 0.12) }}

condition:
  - condition: template
    value_template: >-
      {{ states('sensor.outdoor_temperature') | float(10) < 1
         or states('sensor.forecast_overnight_min') | float(10) < -3 }}
  - condition: template
    value_template: >-
      {{ is_state('person.primary','home') or is_state('input_boolean.away_freeze_guard','on') }}
  - condition: template
    value_template: >-
      {{ (now() - states.sensor.exposed_pipe_temperature.last_updated).total_seconds() < 300 }}

action:
  - choose:
      - conditions:
          - condition: trigger
            id: warn
        sequence:
          - service: notify.mobile_app
            data:
              title: "Freeze risk"
              message: >-
                Exposed run at {{ states('sensor.exposed_pipe_temperature') }} C,
                wind chill {{ wind_chill | round(1) }} C. Trickle arms at 2 C.
      - conditions:
          - condition: trigger
            id: trickle
        sequence:
          - service: valve.open_valve
            target:
              entity_id: "{{ tap }}"
            data:
              flow_limit_lpm: "{{ trickle_lpm }}"
          - wait_for_trigger:
              - platform: numeric_state
                entity_id: sensor.exposed_pipe_temperature
                above: 6
                for: "00:15:00"
            timeout: "{{ max_runtime_h }}:00:00"
            continue_on_timeout: true
          - service: valve.close_valve
            target:
              entity_id: "{{ tap }}"
      - conditions:
          - condition: trigger
            id: release
        sequence:
          - service: valve.close_valve
            target:
              entity_id: "{{ tap }}"

# Pipe clamp failure -> fall back to outdoor below -2 C with wind above 15 km/h.
# Tap fails to open -> escalate the notification with instructions to open a tap
# by hand. Tap fails to close -> 30 minute maximum runtime plus a notification.
触发器 · numeric_state

sensor.exposed_pipe_temperature

暴露管段温度低于 4 °C;2 °C 为第二级触发。

管路防冻:在水温降到 2 °C 前开启远端细流并预警 topology

分步说明

  1. notify.mobile_app在第一级就预警,让人可以做决定,而不是早上才发现细流已经开了一夜。 send at 4 °C · 'exposed run at 4 °C, trickle arms at 2 °C'
  2. valve.far_tap把暴露管段最远端的龙头开到能维持水流的最小流量;15 毫米铜管约需 0.3 L/min 即可抵御 -8 °C 的夜晚。 open · flow limited to 0.4 L/min
  3. valve.far_tap只在温度高于 6 °C 持续 15 分钟后才关闭,避免短暂回暖在黎明前(最冷的时候)提前结束保护。 close when pipe temp > 6 °C for 15 min
  4. sensor.water_used_freeze_guard记录每晚用水量,让卡在开启状态的龙头能被及时发现,而不是等水费单来了才知道。 log · litres per night
分步说明
把传感器夹在最冷的点,而不是最方便的点

最冷的点通常在管道穿墙处、穿过未供暖的空腔处,或紧贴通风夹层处。第一个寒夜里拿红外测温枪沿管走一遍,把传感器夹在读数最低处。图方便安装的结果是:管道已经 2 °C,传感器还显示 8 °C。

保温层包在管夹外面,不是里面

先把管夹直接装在裸铜管上,再用保温棉把两者一起包起来。把保温层垫在管夹下面会切断热通路,传感器测到的是保温层表面。这是管夹安装中最常见的错误。

用标定过的细流,而不是全开龙头

龙头全开一夜会浪费 200–400 升,还可能冲垮化粪池系统。0.4 L/min 的细流整夜约 12 升就能让管路保持在冰点以上。请加装限流器,或使用带位置设定值的电动阀,而不是普通电磁阀。

硬件

型号协议连接在本链路中的作用
Pipe-clamp temperature sensor, insulated over the clamp thread 无线 夹在铜管上并覆盖保温层;未保温的管夹读的是空气温度,预警会晚得多。
Thread motorised tap or valve on the far end of the run thread 有线 开启到标定好的细流;普通电磁阀是全流量,一夜会浪费 200 升以上。
Outdoor temperature and wind sensor thread 无线 提供寒风效应输入,正是它使朝北外墙管段在 4 °C 气温下就会冻结。

失效时怎么办

如果管夹传感器失效,防护回退为「室外温度低于 -2 °C 且风速高于 15 km/h」,精度差一些但偏保守。如果龙头无法开启,通知会升级并提示家庭当晚手动打开一个水龙头。如果龙头无法关闭,30 分钟的最大运行时长会强制关闭并发出通知。

同一触发源的配方